The Renogy 12V 20Ah Deep Cycle is a battery pack with a nominal voltage of 12.8 V nominal, a rated capacity of 20 Ah at 0.5C, 25°C, Lithium iron phosphate cells, dimensions of 7.13 × 3.03 × 6.61 inch, M6 × 1.25 × 10 mm bolts and a continuous discharge of 20 A.

Last updated: 21 September 2026

What we found

  • 10 devices are compared as NOT run by it, by setting each maker's published figures against the other — neither names the pairing.
  • Matched to chargers, by setting each maker's published figures against the other — neither names the pairing.
  • Specifications are published for it, each with its source.

Battery and charging

Cells
Lithium iron phosphate

“Battery Cell Type Lithium Iron Phosphate”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Voltage
12.8 V nominal

“Nominal Voltage 12.8V”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Rated capacity
20 Ah at 0.5C, 25°C

“Rated Capacity (0.5C, 25°C) 20Ah”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Rated charge cycles
4000 cycles at 80% depth of discharge

“Cycle Life (0.5C, 25°C) 4000 Cycles (80% DOD)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Maximum continuous discharge
20 A continuous

“Maximum Continuous Discharge Current 20A”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Series and parallel limit
Up to four in series, four in parallel

“Connection Method Series & Parallel (4S4P)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Highest charge current it will take
20 A

“Maximum Continuous Charge Current 20A”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Charging voltage
14.2 V

“Charge Voltage 14.2V”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Working voltage range
10 V to 14.8 V

“Voltage Range 10V to 14.8V”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Battery care and safety

Ingress protection
IP65

“Protection Rating IP65”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Low-temperature charge protection
Charging stops at 0 °C and resumes at 5 °C

“Charge Low Temperature Protection Trigger Battery Temperature ≤ 32ºF (0ºC) Recover Battery Temperature ≥ 41ºF (5ºC)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Short-circuit cut-off
120 A, and the load has to be removed to reset it

“Short Circuit Protection Trigger Discharge Current ≥ 120A Recover Remove the load”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Temperatures it may be charged in
0 to 55°C when charging

“Charge Temperature Range 32°F to 131°F (0°C to 55°C)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Temperatures it may be run in
-20 to 60°C when running

“Discharge Temperature Range -4°F to 140°F (-20°C to 60°C)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Temperatures it may be stored in
-20 to 60°C in storage

“Storage Temperature Range -4°F to 140°F (-20°C to 60°C)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Size and fit

Overall dimensions
7.13 × 3.03 × 6.61 inch

“Dimension 7.13 x 3.03 x 6.61 in / 181 x 77 x 168 mm”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Torque for the battery terminal nuts
5 to 6 N·m

“Recommended Terminal Torque 44.25 inch·lbs to 53.1 inch·lbs / 5 N·m to 6 N·m”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Stated weight
5.95 lbs

“Weight 5.95 lbs / 2.7 kg”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Terminal thread
M6 × 1.25 × 10 mm bolts

“Terminal Bolt Size M6 x 1.25 x 10 mm”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Group size the maker does not name
A BCI group is claimed but never named

“designed for the drop-in replacement of deep-cycle lead-acid batteries with its standard Battery Council International (BCI) group size”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Other findings

Charge overcurrent protection
Trips at 30 A and recovers by itself after 8 seconds

“Charge Overcurrent Protection Trigger Charge Current ≥ 30A Recover Automatic recovery after 8 seconds”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Discharge overcurrent protection
Trips at 30 A, with a second stage at 60 A

“Discharge Overcurrent Primary Protection Trigger Discharge Current ≥ 30A”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Low temperature discharge protection
Discharge stops at −20 °C and resumes at −15 °C

“Discharge Low Temperature Protection Trigger Battery Temperature ≤ -4ºF (-20ºC) Recover Battery Temperature ≥ 5ºF (-15ºC)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Certification claims

Standards the maker claims
Nine named by the maker, none with a certificate number

“Certification MSDS, UN38.3, FCC, CE, PSE, RCM, IC, RoHS, and UKCA”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

Compatible chargers

These chargers are here because the published figures line up, not because anyone has said they go together — that is our reading of two documents that never mention each other, not a claim by either maker and not a test by us. Even where every figure agrees, these are not established:

  • Which charge profile the charger is actually set to — several publish four or more, and only one of them is this pack’s chemistry
  • What it holds the pack at once bulk charging ends, which is a different figure from the one it boosts to, and which some profiles do not apply at all
  • The charge current the pack will accept, against what the charger delivers into it
  • Whether the charger can restart a pack its own BMS has already disconnected
  • The wiring in between — where a converter feeds a distribution panel, the pack is one load on a circuit rather than a device on the end of a lead

Worth confirming with the charger's manufacturer or a dealer before buying.

Renogy state this pack's charge voltage as 14.2 V — their datasheet reads "Charge Voltage 14.2V".

Neither company names the other, and nobody has tested this pairing.

  • THE GAP RUNS THE OTHER WAY ON THIS ONE. The pack asks for 14.2 V and the charger's Li (LFP) profile boosts to 14.4 V — two tenths above rather than below — and the pack's own stated range runs to 14.8 V, so the charger's figure is inside it. As on every lithium pairing here the charger applies no float stage, so the higher boost figure is not held indefinitely. Worth reading beside the 100Ah trolling-motor pack on the same charger, where the same 14.4 V sits BELOW that pack's stated 14.6 V: one charger setting, two Renogy packs, and it misses both in opposite directions.

  • Set to lithium, WFCO's manual for this converter says it reaches 14.6 VDC in bulk: "boosting the output voltage to 14.6 VDC and allowing the maximum current to flow as required by the loads." That is at or above the figure the pack asks for, where the same maker's WF-8900 tops out at 14.4 V. Bulk runs between one and four hours — the one-hour minimum is for cell balancing rather than charge — and absorption then holds 13.6 V. The lithium profile is selected by a switch on the unit, and an amber LI light shows it is in that mode.

  • This converter decides for itself: WFCO's manual says it will "evaluate the charging cycle of a battery, determine the type of battery being used, and then choose the appropriate charging program(profile)", recognising lead-acid, AGM and lithium. Once it has settled on lithium it charges in two stages and reaches 14.6 VDC in bulk, at or above the figure this pack asks for. The condition matters and is theirs, not ours: the 14.6 V depends on the converter detecting lithium.

Devices whose figures this pack does not meet

Neither maker names the other. These devices publish a draw this pack’s own maker does not rate it to deliver continuously. That is a comparison of two documents and not a manufacturer’s refusal — check both against your own equipment before deciding anything.

The motor's maker asks for 100 Ah minimum for a lead-acid or AGM battery, and 50 Ah to 100 Ah where the battery is lithium, and the battery must be able to supply 60 A of continuous current. This pack is rated 20 Ah and 20 A continuous. The pack's maker permits the series wiring this needs: "Series & Parallel (4S4P)".

Neither company names the other, and this is a comparison of two documents rather than anybody's refusal.

Compared on continuous figures only: nothing here is about surge.

This pack is rated 20 Ah and 20 A continuous.

The pack's maker permits the series wiring this needs: "Series & Parallel (4S4P)".

Minn Kota ask for “at least a 105 amp-hour rating”, in a paragraph about lead-acid: “The motor will operate with any lead acid, deep cycle marine 12-volt battery/batteries.

Source: johnsonoutdoors.widen.net/content/zp8zgjh29h/pdf/Terrova-BT-Installation-2327132rj.pdf

For best results, use a deep cycle, marine battery with at least a 105 amp-hour rating.” This pack is LiFePO4.

Figures compared — they do not meet

Neither maker names the other. What these chargers publish and what this pack publishes do not meet, and each row below says how. That is our comparison of two documents and not a manufacturer’s refusal — check both against your own equipment before deciding anything.

  • Renogy state this pack's charge voltage as 14.2 V — their datasheet reads "Charge Voltage 14.2V". WFCO's own manual gives this converter a target output of 13.6 VDC in normal use, rising to 14.4 VDC only in Bulk Mode, which it leaves "until the current draw drops to approximately five Amps, or until the timer reaches four hours (whichever happens first)". So the converter's normal output is below what this pack is specified to charge at, and 14.2 V is reached only during that Bulk phase. Neither company names the other, and neither has said anything about this pairing.

Sources

  • Renogy 12.8V 20Ah Deep Cycle Lithium Iron Phosphate Battery — User ManualManufacturer document

    Renogy

    Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT1220LFP-TM-G2_12.8V_20Ah_Lithium_Iron_Phosphate_Battery_EN__UM_A1.pdf

    Retrieved September 11, 2026

  • Renogy DCC50S — User Manual, section 6.2 Battery Charging ParametersManufacturer document

    Renogy

    Source: renogy.com/cdn/shop/files/RBC30D1S-G3_G4_RBC50D1S-G6_DC-DC_with_MPPT_EN__UM_B5.pdf

    Retrieved September 14, 2026

  • WFCO WF-9500LiS Series Power Converter Operator ManualManufacturer document

    WFCO Technologies

    Source: forestriverinc.com/files/component-manuals/Electrical/WFCO - Power Converter Model WF-9500LiS Series Operator Manual.pdf

    Retrieved September 20, 2026

  • WFCO WF-9500-AD Series Power Converter Operator ManualManufacturer document

    WFCO Technologies

    Source: forestriverinc.com/files/component-manuals/Electrical/WFCO - Power Converter Model WF-9500 -AD Series Operator Manual.pdf

    Retrieved September 20, 2026

  • WFCO WF-8900 Series Power Converter Operator ManualManufacturer document

    WFCO Technologies

    Source: forestriverinc.com/files/component-manuals/Electrical/WFCO - Power Converter Model WF-8900 Series Operator Manual.pdf

    Retrieved September 19, 2026

  • Progressive Dynamics PD1600 Series Operation GuideManufacturer document

    Progressive Dynamics

    Source: forestriverinc.com/files/component-manuals/Electrical/Progressive Dynamics - Inverter Model PD1600 Series Operation Guide.pdf