Renogy 12V 100Ah Core Mini

MPN RBT12100LFP-M

Renogy
Renogy's product page

The Renogy 12V 100Ah Core Mini is a battery pack with a nominal voltage of 12.8 V nominal, a rated capacity of 100 Ah at 0.5C, 25°C, Lithium iron phosphate cells, dimensions of 9.02 × 5.43 × 8.39 inch, M8 × 1.25 × 12 mm bolts and a continuous discharge of 100 A.

Last updated: 11 September 2026

What we found

  • Matched to devices across several brands, by setting each maker's published figures against the other — neither names the pairing.
  • 5 devices are compared as NOT run by it, by setting each maker's published figures against the other — neither names the pairing.
  • Matched to chargers, by setting each maker's published figures against the other — neither names the pairing.
  • Specifications are published for it, each with its source.

Battery and charging

Cells
Lithium iron phosphate

“Battery Cell Type Lithium Iron Phosphate”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Voltage
12.8 V nominal

“Nominal Voltage 12.8V”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Rated capacity
100 Ah at 0.5C, 25°C

“Rated Capacity (0.5C, 25℃) 100Ah”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Rated charge cycles
5000 cycles at 80% depth of discharge

“Cycle Life (0.5C, 25℃) 5000 Cycles (80% DOD)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Maximum continuous discharge
100 A continuous

“Maximum Continuous Discharge Current 100A”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Peak discharge
300 A for 5 seconds

“Peak Discharge Current 300A@5s”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Series and parallel limit
Up to four in series, eight in parallel

“Connection Method Series & Parallel (4S8P)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Highest charge current it will take
100 A

“Maximum Continuous Charge Current 100A”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Charging voltage
14.4 V

“Charge Voltage 14.4V”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Working voltage range
10 V to 14.8 V

“Voltage Range 10V to 14.8V”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Battery care and safety

Ingress protection
IP65

“Protection Rating IP65”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Temperatures it may be charged in
0 to 50°C when charging

“Charge Temperature Range 32℉ to 122℉ (0℃ to 50℃)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Temperatures it may be run in
-20 to 55°C when running

“Discharge Temperature Range -4℉ to 131℉ (-20℃ to 55℃)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Temperatures it may be stored in
-25 to 65°C in storage

“Storage Temperature Range -13℉ to 149℉ (-25℃ to 65℃)”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Humidity it is rated for
10% to 95% relative humidity

“Operation Relative Humidity 10% to 95%”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Size and fit

Overall dimensions
9.02 × 5.43 × 8.39 inch

“Dimension 9.02 x 5.43 x 8.39 in / 229 x 138 x 213 mm”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Torque for the battery terminal nuts
88.5 in·lbs / 10 N·m

“Recommended Terminal Torque 88.5 in·lbs / 10 N·m”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Stated weight
21.8 lbs

“Weight 21.8 lbs / 9.9 kg”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Terminal thread
M8 × 1.25 × 12 mm bolts

“Terminal Bolt Size M8 x 1.25 x 12 mm”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Certification claims

Standards the maker claims
Nine listed, including IC — which the 300Ah omits

“Certification MSDS, UN38.3, FCC, CE, PSE, RCM, IC, RoHS, UKCA”

Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

Compatible chargers

These chargers are here because the published figures line up, not because anyone has said they go together — that is our reading of two documents that never mention each other, not a claim by either maker and not a test by us. Even where every figure agrees, these are not established:

  • Which charge profile the charger is actually set to — several publish four or more, and only one of them is this pack’s chemistry
  • What it holds the pack at once bulk charging ends, which is a different figure from the one it boosts to, and which some profiles do not apply at all
  • The charge current the pack will accept, against what the charger delivers into it
  • Whether the charger can restart a pack its own BMS has already disconnected
  • The wiring in between — where a converter feeds a distribution panel, the pack is one load on a circuit rather than a device on the end of a lead

Worth confirming with the charger's manufacturer or a dealer before buying.

Renogy state this pack's charge voltage as 14.4 V — their datasheet reads "Charge Voltage 14.4V".

Neither company names the other, and nobody has tested this pairing.

  • Set to lithium, WFCO's manual for this converter says it reaches 14.6 VDC in bulk: "boosting the output voltage to 14.6 VDC and allowing the maximum current to flow as required by the loads." That is at or above the figure the pack asks for, where the same maker's WF-8900 tops out at 14.4 V. Bulk runs between one and four hours — the one-hour minimum is for cell balancing rather than charge — and absorption then holds 13.6 V. The lithium profile is selected by a switch on the unit, and an amber LI light shows it is in that mode.

  • This converter decides for itself: WFCO's manual says it will "evaluate the charging cycle of a battery, determine the type of battery being used, and then choose the appropriate charging program(profile)", recognising lead-acid, AGM and lithium. Once it has settled on lithium it charges in two stages and reaches 14.6 VDC in bulk, at or above the figure this pack asks for. The condition matters and is theirs, not ours: the 14.6 V depends on the converter detecting lithium.

Devices documented to run on this

The figures below line up. Neither manufacturer states that this pack runs this device — that is our reading of what each of them published separately, not a claim by either of them or a test by us. Even where every stated figure agrees, these can still decide it:

  • The device’s published draw is usually a peak, not the load it holds — the two numbers are not the same kind of quantity
  • A maker’s amp-hour minimum and their reserve-capacity minimum can give different answers about the same battery
  • Conditions attached to the chemistry, such as a speed limit for running on lithium
  • Whether the pack may be wired in series at all, where the device needs 24 or 36 volts
  • The charger, which both makers put conditions on and neither supplies
  • Case size, hold-down and terminal type — fitting the space is not being secured in it

Worth confirming with the device's manufacturer or a dealer before buying.

Three of these, identical to each other, wired in series for 36 V.

Only at 36 volts, and on published figures — neither maker has named the other and nobody has tested this pairing — check yours before buying.

The motor's maker asks for 100 Ah minimum for a lead-acid or AGM battery, and 50 Ah to 100 Ah where the battery is lithium, and the battery must be able to supply 60 A of continuous current. This pack is rated 100 Ah and 100 A continuous. The pack's maker permits the series wiring this needs: "Series & Parallel (4S8P)".

Devices whose figures this pack does not meet

Neither maker names the other. These devices publish a draw this pack’s own maker does not rate it to deliver continuously. That is a comparison of two documents and not a manufacturer’s refusal — check both against your own equipment before deciding anything.

Neither company names the other, and this is a comparison of two documents rather than anybody's refusal.

Compared on continuous figures only: nothing here is about surge.

Minn Kota ask for “at least a 105 amp-hour rating”, in a paragraph about lead-acid: “The motor will operate with any lead acid, deep cycle marine 12-volt battery/batteries.

Source: johnsonoutdoors.widen.net/content/zp8zgjh29h/pdf/Terrova-BT-Installation-2327132rj.pdf

For best results, use a deep cycle, marine battery with at least a 105 amp-hour rating.” This pack is LiFePO4.

This pack is rated 100 Ah and 100 A continuous.

The pack's maker permits the series wiring this needs: "Series & Parallel (4S8P)".

Figures compared — they do not meet

Neither maker names the other. What these chargers publish and what this pack publishes do not meet, and each row below says how. That is our comparison of two documents and not a manufacturer’s refusal — check both against your own equipment before deciding anything.

  • Renogy state this pack's charge voltage as 14.4 V — their datasheet reads "Charge Voltage 14.4V". WFCO's own manual gives this converter a target output of 13.6 VDC in normal use, rising to 14.4 VDC only in Bulk Mode, which it leaves "until the current draw drops to approximately five Amps, or until the timer reaches four hours (whichever happens first)". So the converter's normal output is below what this pack is specified to charge at, and 14.4 V is reached only during that Bulk phase. Neither company names the other, and neither has said anything about this pairing.

Sources

  • Renogy Core Series Mini Deep Cycle Lithium Iron Phosphate Battery 12.8V 100Ah/200Ah/300Ah — User Manual (VERSION A0, 31 March 2026)Manufacturer document

    Renogy

    Source: cdn.shopify.com/s/files/1/0631/0137/0483/files/RBT12100LFP-M-G1_RBT12200LFP-M-G1_RBT12300LFP-M-G1_Core_Mini_Battery_CFR_EN__UM_A2.pdf

    Retrieved September 11, 2026

  • WFCO WF-9500LiS Series Power Converter Operator ManualManufacturer document

    WFCO Technologies

    Source: forestriverinc.com/files/component-manuals/Electrical/WFCO - Power Converter Model WF-9500LiS Series Operator Manual.pdf

    Retrieved September 20, 2026

  • WFCO WF-9500-AD Series Power Converter Operator ManualManufacturer document

    WFCO Technologies

    Source: forestriverinc.com/files/component-manuals/Electrical/WFCO - Power Converter Model WF-9500 -AD Series Operator Manual.pdf

    Retrieved September 20, 2026

  • WFCO WF-8900 Series Power Converter Operator ManualManufacturer document

    WFCO Technologies

    Source: forestriverinc.com/files/component-manuals/Electrical/WFCO - Power Converter Model WF-8900 Series Operator Manual.pdf

    Retrieved September 19, 2026

  • Progressive Dynamics PD1600 Series Operation GuideManufacturer document

    Progressive Dynamics

    Source: forestriverinc.com/files/component-manuals/Electrical/Progressive Dynamics - Inverter Model PD1600 Series Operation Guide.pdf

    Retrieved September 20, 2026