Last updated: 11 November 2026
At a glance
What this device draws
- Current it draws
- Under 1 mA
- Supply voltage it runs on
- 6.5 - 70 VDC
- Standing measurement offset
- Less than 40 mA on the 2000 A
- How accurately it reads current
- ± 0.4 %
- How accurately it reads voltage
- ± 0.3 %
“Supply voltage range 6.5 - 70 Vdc Current draw < 1mA Input voltage range, auxiliary battery 6.5 - 70 Vdc”
Source: victronenergy.com/upload/documents/SmartShunt_IP65/9172-Manual_BMV_and_SmartShunt-pdf-en.pdf
“Supply voltage range 6.5 - 70 VDC”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“Offset Less than 10 / 10 / 20 / 40 mA”
Source: victronenergy.com/upload/documents/SmartShunt_IP65/9172-Manual_BMV_and_SmartShunt-pdf-en.pdf
“Accuracy of current measurement ± 0.4 %”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“Accuracy of voltage measurement ± 0.3 %”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
Battery care and safety
- Operating temperature range
- -40 to +50 °C
- Ingress protection
- IP65
- Temperatures it can measure
- -20 to +50 °C
“Operating temperature range -40 +50 °C (-40 – 120 °F)”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“Protection category IP65 (potted)”
Source: victronenergy.com/media/pg/SmartShunt_IP65/en/technical-data.html
“Temperature measurement range -20 +50 °C”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
Size and fit
- Overall dimensions
- 68 x 168 x 100 mm (h x w x d)
- Bolts on the shunt
- M10 bolts
“300A: 44 x 120 x 38 mm 500A: 46 x 120 x 54 mm 1000A: 68 x 168 x 75 mm 2000A: 68 x 168 x 100 mm”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“300 A: M8 500 A, 1000 A, 2000 A: M10 (0.3937 inch)”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
Compatibility
- Bank sizes it can be set to
- 1 to 9999 Ah
“Battery capacity (Ah) 1 - 9999 Ah”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
Buying and owning it
- Days of history it keeps
- 46 days
- VE.Direct port
- Yes
- Cables in the box
- Two 1.5 m fused (1 A) cables
- Temperature sensor
- Optional, ASS000100000
“Number of days trends data is stored 46”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“VE.Direct communication port Yes”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“Two 1.5 m cables with 1 A fuse, for ‘+’ connection and starter battery or midpoint connection”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“Temperature sensor Optional (ASS000100000)”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
Other findings
- Protection category
- IP65, and potted
“Protection category IP65 (potted)”
Source: victronenergy.com/upload/documents/SmartShunt_IP65/9172-Manual_BMV_and_SmartShunt-pdf-en.pdf
Certification claims
- The safety standard on its datasheet
- EN 60335-1
- Automotive standard claimed
- EN 50498
“STANDARDS Safety EN 60335-1”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
“EN-IEC 61000-6-3 Automotive EN 50498”
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
Certifications
- ECE R10-06UN Regulation No. 10 revision 06 — electromagnetic compatibility of vehiclesVerified certification recordIssuer: RDW — Netherlands Vehicle Authority (E4), Type-approval DepartmentCert #E4*10R06/03*5840*00RDW type-approval communication E4*10R06/03*5840*00 — SmartShunt IP65 (all models) — victronenergy.com/upload/documents/Certificate-Automotive-ECE-R10-6-SmartShunt-IP65-(all-models).pdf
Applies in: Contracting parties to UN Regulation No. 10 — the E-mark route, granted by the Netherlands (E4)
RDW type-approval communication E4*10R06/03*5840*00, granted at Zoetermeer on 29 May 2025 and signed by B. P. Loen. The box ticked is "approval granted" rather than "approval extended", and it names four variants: Smartshunt 300A IP65, 500A IP65, 1000A IP65 and 2000A IP65. Tested by Kiwa Assurance B.V. of Woerden, accredited to ISO 17025, under test report 20250011RPT01 dated 17 March 2025. The appendix gives the electrical system rated voltage as 12 or 24 V with NEGATIVE GROUND — the form prints "pos./neg. ground" and strikes "pos." out, following its own instruction to strike out what does not apply. A positive-ground installation is outside what this approval covers. Its scope is electromagnetic compatibility and no more. The test method named is "Electrical disturbance test on voltage supply lines", and the appendix states no vehicle-type restriction and no installation condition. It establishes nothing about the safety of the unit.
Each standard listed is an independent claim about this specific product — one standard does not imply compliance with another.
Sources
- Archived document
Source: victronenergy.com/upload/documents/Datasheet-SmartShunt-IP65-EN-.pdf
Retrieved September 23, 2026
- Archived document
Source: victronenergy.com/upload/documents/SmartShunt_IP65/9172-Manual_BMV_and_SmartShunt-pdf-en.pdf
Retrieved September 21, 2026
- 11. Technical dataArchived document
Source: victronenergy.com/media/pg/SmartShunt_IP65/en/technical-data.html
Retrieved November 11, 2026