Skip to content

Victron Energy MultiPlus-II 48/8000/110-100

Victron Energy's product page

The Victron Energy MultiPlus-II 48/8000/110-100 is a battery charger with dimensions of 642 x 363 x 206 mm and a weight of 41.2 kg.

Last updated: 11 November 2026

Battery and charging

Charger output voltage
57.6V

“Charge voltage 'absorption' 57.6V”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Charger output current
110A

“Charge current house battery (4) 110A”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Shore or generator current it passes
100 A transfer switch

“Transfer switch 32 A 50 A 100 A 100 A 100 A”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

Highest charge current it will take
110 A maximum

“Max. battery charge current (4) 120 /70 / 35 A 220/120/ 70 A 110 A 140 A 200 A”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

Battery care and safety

Ingress protection
IP 22

“Protection category IP 22”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Size and fit

Weight
41.2 kg

“Weight 41.2 kg 48.8 kg 80 kg Dimensions h x w x d 642 x 363 x 206 mm”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Overall dimensions
642 x 363 x 206 mm

“Dimensions h x w x d 642 x 363 x 206 mm”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Compatibility

Battery voltage it runs on
38-66 V at the input

“DC Input voltage range 12 V - 9,5-17 V 24 V - 19-33 V 48 V - 38-66 V”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

Other findings

Absorption voltage
57,6 V absorption

“Charge voltage 'absorption' 14,4 / 28,8 / 57,6 V”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

CE mark date
CE mark from May 2019

“CE MARK DATE: May, 2019”

Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

Declared EU directives
EMC, Low Voltage, RoHS and REACH

Unconfirmed

“EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU RoHS (2011/65/EU and 2015/863/EU) EC REACH Regulation (EC 1907/2006)”

Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

Named on declaration of conformity
Named on the February 2026 EU declaration

“MultiPlus-II 48/8000/110-100 230V”

Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

Charger certifications

IECEE CB Test Certificate NL2-020381 M1, issued by Kiwa Nederland B.V. (Apeldoorn) on 2023-11-28 and signed by Raphael Rader, for a "Battery inverter/charger" found in conformity with IEC 60335-1:2010 with AMD1:2013 and AMD2:2016, and IEC 60335-2-29:2016 with AMD1:2019, under test report 17PP264-33_1. It replaces NL2-020381 of 2022-10-10 "due to update of CBTR to include new models to the family". It names six MultiPlus-II 230V models (with their GX and MultiGrid-II twins): 24/3000/70-32, 48/3000/35-32, 48/5000/70-50, 48/8000/110-100, 48/10000/140-100 and 48/15000/200-100. THIS CERTIFICATE'S RATINGS FOR THIS MODEL ARE MISPRINTED: under the 48/8000, 48/10000 and 48/15000 it repeats the 24/3000's, 48/3000's and 48/5000's figures word for word (the 48/8000 appears as "24Vdc nom, 19-33Vdc 125A max"). Kiwa's IEC 62109 certificate DE/PTZ/0356/M1 prints this model's real ratings. The model is named in the certificate's Model / Type Ref. list, so the certificate covers it; its ratings block is not used as a figure for anything.

IECEE CB Test Certificate DE/PTZ/0356/M1, issued by Kiwa Primara GmbH (Kaufbeuren) on 2023-10-25 and signed by Tanja Rottach, for a "Battery inverter/charger" found in conformity with IEC 62109-1:2010 and IEC 62109-2:2011, under test reports 17PP264-31_1 and 17PP264-32_1. It replaces DE/PTZ/0356 of 2022-09-08 and adds the 48/8000/110-100, 48/10000/140-100 and 48/15000/200-100. It names the same six MultiPlus-II 230V models as the IEC 60335 certificate. IEC 62109 is the safety standard for power converters in photovoltaic systems, which is why a battery inverter/charger that can run grid-parallel carries it.

Each standard listed is an independent claim about this specific product — one standard does not imply compliance with another.

Sources

  • Kiwa Nederland B.V. certificate NL2-020381 M1 — Victron MultiPlus-IICertification body record

    Kiwa Nederland B.V.

    Source: victronenergy.com/upload/documents/Certificate-IEC-60335-1-60335-2-MultiPlus-II-(GX)-3kVA,-5kVA,-8kVA,-10kVA-&-15kVA.pdf

    Retrieved September 23, 2026

  • Kiwa Primara GmbH certificate DE/PTZ/0356/M1 — Victron MultiPlus-IICertification body record

    Kiwa Primara GmbH

    Source: victronenergy.com/upload/documents/Certificate-EN-IEC-62109-1-2-all-MultiPlus-II-(GX).pdf

    Retrieved September 23, 2026

  • Archived document

    Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

    Retrieved September 16, 2026

  • Archived document

    Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

    Retrieved September 23, 2026

  • 7. Technical specificationsArchived document

    Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

    Retrieved November 11, 2026