The Victron Energy MultiPlus-II 12/5000/220-50 is a battery charger with dimensions of 702 X 345 X 152 mm, a weight of 33 kg and an ingress rating of IP22.
Last updated: 11 November 2026
Battery and charging
- Charger output voltage
- 14.4V
- Charger output current
- 50A
- Shore or generator current it passes
- 50 A transfer switch
- Highest charge current it will take
- 220 A maximum
“Charge voltage 'absorption' 14.4V”
Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html
“Charge current house battery (4) 50A”
Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html
“Transfer switch 32 A 50 A 100 A 100 A 100 A”
Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf
“Max. battery charge current (4) 120 /70 / 35 A 220/120/ 70 A 110 A 140 A 200 A”
Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf
Battery care and safety
- Ingress protection
- IP22
“Material & Colour Steel, blue RAL 5012 Protection category: IP22”
Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html
Size and fit
- Weight
- 33 kg
- Overall dimensions
- 702 X 345 X 152 mm
“Weight 33kg 30kg 30kg Dimensions h x w x d 702 X 345 X 152 mm”
Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html
“Dimensions h x w x d 702 X 345 X 152 mm”
Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html
Compatibility
- Battery voltage it runs on
- 9,5-17 V at the input
“DC Input voltage range 12 V - 9,5-17 V 24 V - 19-33 V 48 V - 38-66 V”
Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf
Other findings
- Absorption voltage
- 14,4 V absorption
- Automotive standard on the declaration
- ECE R10-6, declared for 12 V and 24 V models only
- CE mark date
- CE mark from May 2019
- Declared EU directives
- EMC, Low Voltage, RoHS and REACH
- Named on declaration of conformity
- Named on the February 2026 EU declaration
“Charge voltage 'absorption' 14,4 / 28,8 / 57,6 V”
Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf
“ECE R10-6*(*Only for MultiPlus-II 12/xxxxx/xxx-xxx 230V and 24/xxxxx/xxx-xxx 230V models)”
Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf
“CE MARK DATE: May, 2019”
Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf
Unconfirmed
“EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU RoHS (2011/65/EU and 2015/863/EU) EC REACH Regulation (EC 1907/2006)”
Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf
“MultiPlus-II 12/5000/220-50 230V”
Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf
Sources
- Archived document
Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf
Retrieved September 16, 2026
- Archived document
Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf
Retrieved September 23, 2026
- 7. Technical specificationsArchived document
Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html
Retrieved November 11, 2026