Skip to content

Victron Energy MultiPlus-II 12/5000/220-50

Victron Energy's product page

The Victron Energy MultiPlus-II 12/5000/220-50 is a battery charger with dimensions of 702 X 345 X 152 mm, a weight of 33 kg and an ingress rating of IP22.

Last updated: 11 November 2026

Battery and charging

Charger output voltage
14.4V

“Charge voltage 'absorption' 14.4V”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Charger output current
50A

“Charge current house battery (4) 50A”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Shore or generator current it passes
50 A transfer switch

“Transfer switch 32 A 50 A 100 A 100 A 100 A”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

Highest charge current it will take
220 A maximum

“Max. battery charge current (4) 120 /70 / 35 A 220/120/ 70 A 110 A 140 A 200 A”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

Battery care and safety

Ingress protection
IP22

“Material & Colour Steel, blue RAL 5012 Protection category: IP22”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Size and fit

Weight
33 kg

“Weight 33kg 30kg 30kg Dimensions h x w x d 702 X 345 X 152 mm”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Overall dimensions
702 X 345 X 152 mm

“Dimensions h x w x d 702 X 345 X 152 mm”

Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

Compatibility

Battery voltage it runs on
9,5-17 V at the input

“DC Input voltage range 12 V - 9,5-17 V 24 V - 19-33 V 48 V - 38-66 V”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

Other findings

Absorption voltage
14,4 V absorption

“Charge voltage 'absorption' 14,4 / 28,8 / 57,6 V”

Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

Automotive standard on the declaration
ECE R10-6, declared for 12 V and 24 V models only

“ECE R10-6*(*Only for MultiPlus-II 12/xxxxx/xxx-xxx 230V and 24/xxxxx/xxx-xxx 230V models)”

Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

CE mark date
CE mark from May 2019

“CE MARK DATE: May, 2019”

Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

Declared EU directives
EMC, Low Voltage, RoHS and REACH

Unconfirmed

“EMC Directive 2014/30/EU Low Voltage Directive 2014/35/EU RoHS (2011/65/EU and 2015/863/EU) EC REACH Regulation (EC 1907/2006)”

Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

Named on declaration of conformity
Named on the February 2026 EU declaration

“MultiPlus-II 12/5000/220-50 230V”

Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

Sources

  • Archived document

    Source: victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf

    Retrieved September 16, 2026

  • Archived document

    Source: victronenergy.com/upload/documents/DoC-MultiPlus-II-(EU)-0226.pdf

    Retrieved September 23, 2026

  • 7. Technical specificationsArchived document

    Source: victronenergy.com/media/pg/MultiPlus-II_230V/en/technical-specifications-mp-ii-230v.html

    Retrieved November 11, 2026