Battery and charging

What it draws on standby
Sources disagree
  • <2 watts (fan off, display/LEDs off)

    “Tare loss / nighttime power consumption <2 watts (fan off, display/LEDs off)”

    Source: invertersupply.com/media/data/Pt100Datass.pdf

  • <4 watts (fan off, display/LEDs off)

    “Tare Loss/Night-time Power Consumption <4 watts (fan off, display/LEDs off)”

    Source: ressupply.com/documents/magnum/PT-100_Installation_Manual.pdf

Rated output power
6600 watts

“Maximum output power 6600 watts”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

While the battery is charging
Automatic three-stage (bulk, absorption, float) charge with manual equalization

“Charger regulation method Automatic three-stage (bulk, absorption, float) charge with manual equalization”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Input voltage
(VBat + 8V) to 187 VDC

“PV Operating Voltage (VBat + 8V) to 187 VDC”

Source: ressupply.com/documents/magnum/PT-100_Installation_Manual.pdf

Charger output voltage
Sources disagree
  • 10 to 66 VDC

    “Battery charger output voltage range 10 to 66 VDC”

    Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

  • 1 to 66 VDC

    “Battery Charger Output Voltage Range 1 to 66 VDC”

    Source: ressupply.com/documents/magnum/PT-100_Installation_Manual.pdf

Charger output current
100 ADC (from -20 °C to +40 °C) with proportional power reduction up to 60 °C ambient

“Continuous charger output current 100 ADC (from -20 °C to +40 °C) with proportional power reduction up to 60 °C ambient”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Maximum efficiency
Sources disagree
  • 99% typical

    “6600 watts 99% typical <4 watts (fan off, display/LEDs off)”

    Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

  • >99% (98% typical)

    “Peak (and Full Power) Efficiency >99% (98% typical)”

    Source: ressupply.com/documents/magnum/PT-100_Installation_Manual.pdf

Battery care and safety

Operating temperature range
-20° C to +60° C (-4° F to 140° F)

“Operating temperature -20° C to +60° C (-4° F to 140° F)”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Temperatures it may be stored in
-40° C to +70° C (-40° F to 158° F)

“Nonoperating temperature -40° C to +70° C (-40° F to 158° F)”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Size and fit

Overall dimensions
8.5” x 15.5” x 4.0” (21.6 cm x 39.4 cm x 10.2 cm)

“Unit dimensions (w x h x d) 8.5” x 15.5” x 4.0” (21.6 cm x 39.4 cm x 10.2 cm)”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Stated weight
Sources disagree
  • 13.6 lb (6.2 kg)

    “13.6 lb (6.2 kg) 18 lb (8.2 kg)”

    Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

  • Unit: 12.5 lb (5.7 kg) / Shipping: 15 lb (6.8 kg)

    “Weight Unit: 12.5 lb (5.7 kg) / Shipping: 15 lb (6.8 kg)”

    Source: ressupply.com/documents/magnum/PT-100_Installation_Manual.pdf

How it mounts
Mounted on a vertical surface (wall) or installed on MP or MMP enclosure

“Mounting Mounted on a vertical surface (wall) or installed on MP or MMP enclosure”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Compatibility

Battery voltage window
12, 24, or 48 VDC

“Nominal battery voltage range 12, 24, or 48 VDC”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Identity

Model code
PT-100

“PT-100 CHARGE CONTROLLER Maximize Energy Harvest and Improve Battery Life”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Certification claims

Certification claimed by the manufacturer
ETL Listed to UL/cUL 1741, CSA C22.2 #107.1-01, CE

“Listings ETL Listed to UL/cUL 1741, CSA C22.2 #107.1-01, CE”

Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

Sources

  • Archived document

    Source: ressupply.com/documents/magnum/PT-100_Data_Sheet.pdf

    Retrieved October 18, 2026

  • Archived document

    Source: ressupply.com/documents/magnum/PT-100_Installation_Manual.pdf

    Retrieved October 18, 2026

  • Archived document

    Source: invertersupply.com/media/data/Pt100Datass.pdf