Skip to content

Progressive Dynamics PD4045/60 Inteli-Power Converter

Progressive Dynamics' product page

Last updated: 21 September 2026

Battery and charging

Mains input it accepts
105 to 130 V AC

“ll supply "clean" power from input voltages that range from 105 - 130VAC.”

Source: forestriverinc.com/files/component-manuals/Electrical/Progressive Dynamics - Power Converter Model PD4000 Series Operation Guide.pdf

Other findings

Charge mode behaviour
Three modes, chosen automatically

“automatically selects one of three operating modes (normal, boost and storage) to provide the correct charge level to the batteries.”

Source: forestriverinc.com/files/component-manuals/Electrical/Progressive Dynamics - Power Converter Model PD4000 Series Operation Guide.pdf

Nominal output voltage
13.6 V DC nominal

“PD4045/60 - The full rated load is available for load, battery charging or both. When functioning as a regulated battery charger the converter has a nominal voltage output of 13.6 VDC. The system is designed to sense voltage on the battery and automatically se”

Source: forestriverinc.com/files/component-manuals/Electrical/Progressive Dynamics - Power Converter Model PD4000 Series Operation Guide.pdf

Output mode switch
Optional LI/LA switch: 14.6 V fixed or 13.6 V managed

“The optional OUTPUT MODE SWITCH sets the converter output to either a constant 14.6VDC with the Charge Wizard ® disabled (switch in 'LI' position) or a nominal 13.6VDC with full Charge Wizard ® function (switch in 'LA' position).”

Source: forestriverinc.com/files/component-manuals/Electrical/Progressive Dynamics - Power Converter Model PD4000 Series Operation Guide.pdf

Sources

  • Archived document

    Source: forestriverinc.com/files/component-manuals/Electrical/Progressive Dynamics - Power Converter Model PD4000 Series Operation Guide.pdf

    Retrieved September 20, 2026