Skip to content

Xantrex 815-2012

Last updated: 25 October 2026

Battery and charging

Charger output current
100 A

“Output current (continuous at 25°C) 100 A 150 A”

Source: xantrex.com/wp-content/uploads/2021/12/20241121_FREEDOMSW_12V_Datasheet.pdf

Charger mains input
85 - 140 Vac

“Input AC voltage range 85 - 140 Vac 85 - 140 Vac”

Source: xantrex.com/wp-content/uploads/2021/12/20241121_FREEDOMSW_12V_Datasheet.pdf

Peak output
4000 W

“Surge rating (5 seconds) 4000 W 6000 W”

Source: xantrex.com/wp-content/uploads/2021/12/20241121_FREEDOMSW_12V_Datasheet.pdf

Inverter output
True sine wave

“Output wave form True sine wave True sine wave”

Source: xantrex.com/wp-content/uploads/2021/12/20241121_FREEDOMSW_12V_Datasheet.pdf

Battery types supported by the charger
Custom / Flooded / Gel / AGM*

“Compatible battery types Custom / Flooded / Gel / AGM* Custom / Flooded / Gel / AGM*”

Source: xantrex.com/wp-content/uploads/2021/12/20241121_FREEDOMSW_12V_Datasheet.pdf