VMAXTANKS XTR27-110
The VMAXTANKS XTR27-110 is a battery pack with a nominal voltage of 12 Volts, a capacity of 110Ah at the 20-hour rate and a reserve capacity of 220 minutes (25A to 10.5V).
Last updated: 20 October 2026
Battery and charging
- Battery weight
- 67 lbs (30.4 kg)
- Voltage
- 12 Volts
- Battery type
- Dual Purpose AGM (Starting + Deep Cycle)
- Capacity, at the 20-hour rate
- 110Ah
- Reserve capacity
- 220 minutes (25A to 10.5V)
- Cold cranking amps
- 730 Amps
- Charging voltage
- 14.6V - 14.9V
- Float voltage
- 13.5V - 13.8V
“Terminals SAE Posts + 5/16" Studs Polarity + Left / - Right Length 12.0" (305 mm) Width 6.6" (168 mm) Height 8.5" (216 mm) / 9.2" (234 mm) w/terminals Weight 67 lbs (30.4 kg)”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“Type Dual Purpose AGM (Starting + Deep Cycle) Group Size 27 Nominal Voltage 12 Volts Cold Cranking Amps 730 Amps Marine Cranking Amps 880 Amps”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“VMAX XTR27-110 AGM Deep Cycle Battery Datasheet Type Dual Purpose AGM (Starting + Deep Cycle) Group Size 27 Nominal Voltage 12 Volts”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“Cold Cranking Amps 730 Amps Marine Cranking Amps 880 Amps Capacity (20-hour rate) 110Ah Reserve Capacity 220 minutes (25A to 10.5V)”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“Capacity (20-hour rate) 110Ah Reserve Capacity 220 minutes (25A to 10.5V) Energy 1.46 kWh Terminals SAE Posts + 5/16" Studs”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“Group Size 27 Nominal Voltage 12 Volts Cold Cranking Amps 730 Amps Marine Cranking Amps 880 Amps Capacity (20-hour rate) 110Ah”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“Weight 67 lbs (30.4 kg) Charging Current 10 - 35 Amps Charging Voltage 14.6V - 14.9V Float Voltage 13.5V - 13.8V Discharge Temp Range -4°F - 140°F”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“Charging Current 10 - 35 Amps Charging Voltage 14.6V - 14.9V Float Voltage 13.5V - 13.8V Discharge Temp Range -4°F - 140°F Charging Temp Range 32°F - 120°F”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
Battery care and safety
- Charge cycles, as claimed
- 2,600 Cycles at 25% Depth of Discharge (DOD)
- Operating temperature range
- -4°F - 140°F
“Storage Temp Range -4°F - 140°F Float Service Life 10 - 12 Years Cycle Life 2,600 Cycles at 25% Depth of Discharge (DOD) 1,000 Cycles at 50% DOD 600 Cycles at 80% DOD”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
“Float Voltage 13.5V - 13.8V Discharge Temp Range -4°F - 140°F Charging Temp Range 32°F - 120°F Storage Temp Range -4°F - 140°F”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
Size and fit
- Terminals
- SAE Posts + 5/16" Studs
“Reserve Capacity 220 minutes (25A to 10.5V) Energy 1.46 kWh Terminals SAE Posts + 5/16" Studs Polarity + Left / - Right Length 12.0" (305 mm)”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
Identity
- Model code
- XTR27-110
“VMAX XTR27-110 AGM Deep Cycle Battery Datasheet Type Dual Purpose AGM (Starting + Deep Cycle) Group Size 27 Nominal Voltage 12 Volts”
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
Sources
- Archived document
Source: gmienergy.com/content/brands/vmax/datasheets/vmax-xtr27-110-battery-datasheet.pdf
Retrieved October 12, 2026