Skip to content

Epoch Batteries B4850A 51.2V 50Ah LiFePO4 Battery Pack

SKU B4850A

Epoch Batteries
Epoch Batteries' product page

The Epoch Batteries B4850A 51.2V 50Ah LiFePO4 Battery Pack is a battery pack with a nominal voltage of 51.2V, a nominal capacity of 50Ah and 2.56 kWh of energy.

Last updated: 26 October 2026

Battery and charging

Maximum charge voltage
56.8 V charge

“Internal resistance @1khz AC ≤ 3 0mΩ 2.5 C harge voltage range 56.8 2.6 Float voltage range 54.4 ~ 55.2 V 2.7 Allowed MAX charge cur rent 100 A (1 50A @ 10 s) 2.8 Recommend c harge current 50A 2.9 Allowed MAX discharge current 1 00 A (1 50A@30s) 2.10 Recommend d ischa r ge current 10 0A 2.1 2 Short circuit protection 5 00A@ 500 μs 2. 1 3 End of discharge I nverter/ L oad cut off 44. 8 V BLVD 4 0.0V”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Energy
2.56 kWh

“Nominal […] 2.56 kWh”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Voltage
51.2V

“2.1 Nominal voltage 51.2V 2.2 Nominal […] 2.56 kWh”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Nominal capacity
50Ah

“Nominal […] 50Ah”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Maximum charge current, as the maker labels it
100 A, and 150 A for 10 s

“Internal resistance @1khz AC ≤ 3 0mΩ 2.5 C harge voltage range 56.8 2.6 Float voltage range 54.4 ~ 55.2 V 2.7 Allowed MAX charge cur rent 100 A (1 50A @ 10 s) 2.8 Recommend c harge current 50A 2.9 Allowed MAX discharge current 1 00 A (1 50A@30s) 2.10 Recommend d ischa r ge current 10 0A 2.1 2 Short circuit protection 5 00A@ 500 μs 2. 1 3 End of discharge I nverter/ L oad cut off 44. 8 V BLVD 4 0.0V”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Float voltage
A band, 54.4 to 55.2 V

“Internal resistance @1khz AC ≤ 3 0mΩ 2.5 C harge voltage range 56.8 2.6 Float voltage range 54.4 ~ 55.2 V 2.7 Allowed MAX charge cur rent 100 A (1 50A @ 10 s) 2.8 Recommend c harge current 50A 2.9 Allowed MAX discharge current 1 00 A (1 50A@30s) 2.10 Recommend d ischa r ge current 10 0A 2.1 2 Short circuit protection 5 00A@ 500 μs 2. 1 3 End of discharge I nverter/ L oad cut off 44. 8 V BLVD 4 0.0V”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Other findings

Low voltage disconnect
Load cut-off 44.8 V, BLVD 40.0 V

“Internal resistance @1khz AC ≤ 3 0mΩ 2.5 C harge voltage range 56.8 2.6 Float voltage range 54.4 ~ 55.2 V 2.7 Allowed MAX charge cur rent 100 A (1 50A @ 10 s) 2.8 Recommend c harge current 50A 2.9 Allowed MAX discharge current 1 00 A (1 50A@30s) 2.10 Recommend d ischa r ge current 10 0A 2.1 2 Short circuit protection 5 00A@ 500 μs 2. 1 3 End of discharge I nverter/ L oad cut off 44. 8 V BLVD 4 0.0V”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Recommended discharge current
100 A — the same as the maximum

“Internal resistance @1khz AC ≤ 3 0mΩ 2.5 C harge voltage range 56.8 2.6 Float voltage range 54.4 ~ 55.2 V 2.7 Allowed MAX charge cur rent 100 A (1 50A @ 10 s) 2.8 Recommend c harge current 50A 2.9 Allowed MAX discharge current 1 00 A (1 50A@30s) 2.10 Recommend d ischa r ge current 10 0A 2.1 2 Short circuit protection 5 00A@ 500 μs 2. 1 3 End of discharge I nverter/ L oad cut off 44. 8 V BLVD 4 0.0V”

Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

Sources

  • Archived document

    Source: cdn.shopify.com/s/files/1/0251/0484/2798/files/Epoch_B4850A.pdf?v=1704491290

    Retrieved October 15, 2026