Battery and charging

Charging voltage range
55.6 – 58V, as the maker suggests

Row from the maker’s page: “Charging Voltage Range” | “55.6 – 58V”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Maximum charge voltage

The maker’s own documents give different figures

58.4V maximum

48V LiFePO4 Golf Cart Battery | Big Battery · retrieved 15 September 2026

“Max Charge Voltage: 58.4V Operating Voltage Range: 48 – 58.8V”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

EAGLE2-SpecSheet-1.1-2.pdf · retrieved 15 September 2026

“Max Charge Voltage 29.2V 29.2V 58.4V Operating Voltage Range 24V - 28.8V 24V - 28.8V 48V - 58.8V Suggested Low Voltage Cutoff 24V - 25.4V 24V - 25.4V 48V - 50.8V BMS Cutoff Range 21V - 23.5V 21V - 23.5V 42V - 47V Cell Configuration 8S 8S 16S”

Source: bigbattery.com/wp-content/uploads/2024/01/EAGLE2-SpecSheet-1.1-2.pdf

58.8V in the manual, against 58.4V on the product page

EAGLE2Manual-Digital-V1.pdf · retrieved 15 September 2026

“Charging Voltage Range 27.8V - 29V 55.6V - 58.4V Max Charge Voltage 29.2V 58.8V Operating Voltage Range 24V - 28.8V 48V - 58V”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Communications bus
CANBus

Row from the maker’s page: “Communications” | “CANBus”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Rated charge cycles
4000-6000 cycles at 80% DOD, measured at 0.5C

“the EAGLE 2 has a lifespan of over 10 years and is engineered to withstand more than 4000 - 6000 cycles at 80% Depth of Discharge (DOD) at a rate of 0.5C.”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Cell arrangement
16S

Row from the maker’s page: “Cell Configuration” | “16S”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Maximum continuous discharge
60A continuous, 3072W

“Max Cont. Discharge Current 100A 100A 60A Max Continuous Power 2560W 2560W 3072W Max Discharge Peak Current 200A (Max 5 seconds) 200A (Max 5 seconds) 200A (Max 3 seconds) Max Charge Current 64A 64A 30A”

Source: bigbattery.com/wp-content/uploads/2024/01/EAGLE2-SpecSheet-1.1-2.pdf

Peak discharge
200A (Max 3 seconds)

Row from the maker’s page: “Max Discharge Peak Current” | “200A (Max 3 seconds)”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Series and parallel limit
Up to (10) Parallel

Row from the maker’s page: “Max Connections” | “Up to (10) Parallel”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Highest charge current it will take
30A charging

“Max Cont. Discharge Current 100A 100A 60A Max Continuous Power 2560W 2560W 3072W Max Discharge Peak Current 200A (Max 5 seconds) 200A (Max 5 seconds) 200A (Max 3 seconds) Max Charge Current 64A 64A 30A”

Source: bigbattery.com/wp-content/uploads/2024/01/EAGLE2-SpecSheet-1.1-2.pdf

Working voltage range
48 – 58.8V

“Operating Voltage Range: 48 – 58.8V Suggested Low Voltage Cutoff: 48 – 50.8V”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Battery care and safety

Where its BMS cuts off
42 – 47V, where the pack's own protection acts

Row from the maker’s page: “BMS Cutoff Range” | “42 – 47V”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Suggested low-voltage cut-off
48 – 50.8V, suggested for your equipment

Row from the maker’s page: “Suggested Low Voltage Cutoff” | “48 – 50.8V”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Ingress protection
IP67 / NEMA 6

Row from the maker’s page: “Protection Rating” | “IP67 / NEMA 6”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Temperatures it may be charged in
-4°F – 131°F (-20°C – 55°C)

Row from the maker’s page: “Charge Temperature Range” | “-4°F – 131°F (-20°C – 55°C)”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Temperatures it may be run in
-4°F – 140°F (-20°C – 60°C)

Row from the maker’s page: “Discharge Temperature Range” | “-4°F – 140°F (-20°C – 60°C)”

Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Other findings

Maximum ambient for discharge
above 55°C (131°F)

“charge nor discharge battery when ambient temperature is above 55°C (131°F).”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Maximum parallel units
Ten in parallel, and it has a heater

“Max Connections Up to (10) Parallel Up to (10) Parallel Up to (10) Parallel Protection Rating IP67 IP67 IP67 Communications No CANBus CANBus Heating Function Yes Yes Yes”

Source: bigbattery.com/wp-content/uploads/2024/01/EAGLE2-SpecSheet-1.1-2.pdf

Recommended current rate
0.5C, half the rated maximum

“battery charge and discharge current at a 0.5 C-rating.”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Self heating behaviour
Heats to above 0°C first, then charges

“The battery can be charged in freezing temperatures (-20°C / -4°F) thanks to an automatic self-heating function. When charging is detected, heating will start until the battery temperature is above 0°C (32°F) and then charging will start.”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Sleep mode timeout
Sleeps after 120 hours with no real current

“If currents above these values are not detected for 120 hr., the battery enters Sleep Mode.”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

State of charge LED bands
4 LEDs 90-100%, 3 LEDs 70-89%, 2 LEDs 25-69%, 1 LED 0-24%

“4 LEDs on = 90% - 100% 3 LEDs on = 70% - 89% 2 LEDs on = 25% - 69% 1 LEDs on = 0% - 24%”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Storage duration by temperature
3 months at -5-35 °C, 12 months at 0-25 °C

“Storage Temp. Range (SoC >50%) 23ºF - 95ºF (-5ºC - 35ºC) (Max 3 months) 32ºF - 77ºF (0ºC - 25ºC) (Max 12 months)”

Source: bigbattery.com/wp-content/uploads/2024/01/EAGLE2-SpecSheet-1.1-2.pdf

Storage maintenance charge
56V at 30A CC/CV, stopping at 5A; every 9, 6 or 3 months by temperature

“≤20ºC Once / 9M 56V 30A CC/CV Charging to 56V Cut-Off Current: 5A 48V EAGLE 2 20ºC ~ 30ºC Once / 6M 30ºC ~ 40ºC Once / 3M”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Storage state of charge
At least 50%, and a full pack taken down to 80% first

“charge them to at least 50% SOC. Do not store batteries that are fully discharged. In the case of a fully charged battery, it should be discharged to 80% SOC before it is stored.”

Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

Devices documented to run on this

The figures below line up. Neither manufacturer states that this pack runs this device — that is our reading of what each of them published separately, not a claim by either of them or a test by us. Even where every stated figure agrees, these can still decide it:

  • The device’s published draw is usually a peak, not the load it holds — the two numbers are not the same kind of quantity
  • A maker’s amp-hour minimum and their reserve-capacity minimum can give different answers about the same battery
  • Conditions attached to the chemistry, such as a speed limit for running on lithium
  • Whether the pack may be wired in series at all, where the device needs 24 or 36 volts
  • The charger, which both makers put conditions on and neither supplies
  • Case size, hold-down and terminal type — fitting the space is not being secured in it

Worth confirming with the device's manufacturer or a dealer before buying.

  • One of these.

    Only on the 48 volt model, and on published figures — EAGLE 2 48V 32Ah is rated 60 A continuous and Rhodan rate this motor at up to 50 A — check yours before buying.

    Rhodan state this system runs on 24, 36 or 48 volts depending on the model, and that its "system current draw will vary with thrust level up to a maximum of 50 amps at 100% thrust". This pack is 51.2 V nominal — what the industry sells as 48 volts — and its maker rate it at 60 A continuous, with a peak of 200A (Max 3 seconds), leaving 10 A of headroom at the motor's hardest moment. The two figures are different kinds of number: Rhodan's is a peak draw and the pack's is a continuous rating, so the comparison runs the cautious way round. Rhodan also ask for a 60 amp breaker. BigBattery's 60 amps continuous is also exactly the breaker rating Rhodan ask for, at 60 amps. The two figures come from different companies and neither was set with the other in mind, so the agreement is a coincidence worth noticing rather than a design pairing. Neither company has named the other and nobody has tested the pairing.

    Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

Sources

  • BigBattery — EAGLE 2 48V 32AhManufacturer battery page

    BigBattery

    Source: bigbattery.com/products/48v-eagle-2-lifepo4-32ah-1-63kwh

    Retrieved September 15, 2026

  • Archived document

    Source: bigbattery.com/wp-content/uploads/2024/04/EAGLE2Manual-Digital-V1.pdf

    Retrieved September 15, 2026